# What is the environmental impact of air conditioning?

**Author**: Sébastien Pierfederici
**Published**: 2026-06-24
**Updated**: 2026-10-24
**Section**: Explained
**Canonical URL**: https://projetcelsius.com/en/blog/air-conditioning-environmental-impact/
**French original**: https://projetcelsius.com/blog/impact-environnemental-climatisation/
**Source**: Projet Celsius (https://projetcelsius.com/en/), a climate strategy consultancy of engineers and PhDs based in Paris and Marseille.

> In France, the electricity used by an air conditioner emits **5 to 10 times less CO2** than elsewhere in Europe, thanks to a decarbonised electricity mix (around 30 gCO2e/kWh). Refrigerant leaks can therefore outweigh consumption. Multicriteria life cycle assessment (LCA) adds the urban heat island, rebound effects and rare metals. See also our guide [How can you cool without an air conditioner?](https://projetcelsius.com/en/blog/air-conditioning-alternatives/) and our [Bilan Carbone® versus LCA comparison](https://projetcelsius.com/en/blog/lca-vs-carbon-footprint/).

## Key takeaways

- **In France, the electricity consumed by air conditioning has a small carbon impact.** France's very low-carbon electricity mix makes it 5 to 10 times less emissions-intensive than elsewhere in Europe. Attention therefore shifts to refrigerant leaks and impacts that carbon calculations do not show.
- **In France, refrigerant leaks outweigh electricity.** For an R32 split system losing 5% of its charge each year, they represent around 2 times the emissions from electricity consumed; with the older R410A, whose GWP is 3 times higher, the gap widens further. They do not appear on the bill, and this is what F-Gas regulation seeks to address.
- **The solution differs depending on what you examine.** Carbon depends on use (electricity and refrigerant leaks), metal resource depletion on manufacturing, and the ozone indicator on refrigerant production.
- **The F-Gas timetable tightens from 2027.** Refrigerants with a GWP of 150 or more will be prohibited in monobloc air conditioners of 12 kW or less placed on the market from 1 January 2027, then in air-to-air split systems of the same capacity from 1 January 2029. R32 and R454B (GWP 466) will then disappear from these small models in favour of refrigerants such as R290 (propane), with a near-zero GWP. Equipment bought today can still be used and maintained after these dates.

When offices exceed 30 °C on a heatwave afternoon, the question arises of whether to air-condition them, and at what cost to the environment. This article first gives an order-of-magnitude carbon figure, then explains what that figure does not cover, and finally offers a multicriteria assessment whose verdict changes with the indicator examined. Cooling needs will also depend on location: [the number of tropical nights by municipality by 2050](https://projetcelsius.com/en/blog/where-to-live-in-france-2050-climate-map/) ranges from 3 to more than 70 depending on the area.

## How much CO₂ does air conditioning emit in France?

The calculation relies on multiplication: **energy consumed × electricity emission factor**. We are discussing a product carbon footprint here, rather than an organisation's Bilan Carbone® (the French carbon accounting method): the former measures the CO2 emissions from equipment and its use, the latter all the emissions of an organisation. In France, this factor is low: around 30 gCO2e/kWh over the life cycle according to the 2024 figures from RTE, the French electricity transmission operator. That is **around 10 times less** than in Germany, more than 20 times less than in Poland and around 7 times less than the European average. This still does not allow claims of [carbon-neutral air conditioning](https://projetcelsius.com/en/blog/carbon-neutral-claims-what-companies-can-say/): an organisation's neutrality remains a legally regulated concept.

An air conditioner is technically an air-to-air heat pump: it does not produce cold, but moves heat from inside to outside. This thermodynamic principle is the same for a portable monobloc (2-3 kW cooling capacity, occasional cooling for one room) and a wall-mounted split (2-7 kW, living room or small office). It also applies to a commercial VRF/VRV (variable refrigerant flow) system (15-150 kW, multi-zone building with energy recovery between simultaneously hot and cold zones) and to a reversible air-to-water or ground-source heat pump. Comparing their [SEER](https://projetcelsius.com/en/glossary/seer/) (Seasonal Energy Efficiency Ratio) alone is therefore insufficient: installed cooling capacity and actual use matter just as much.

The integrated calculator lets you simulate a specific case: floor area, ceiling height, equipment type, refrigerant, months of use, European country. Real-time output: consumption, cost, annual emissions and cumulative emissions over 17 years (typical lifespan), comparison of the grid's average and peak mixes. The resulting use-phase footprint is then complemented by the multicriteria assessment.

> **A timing nuance: France's mix changes on heatwave evenings.**  France's average mix of 30 gCO₂/kWh conceals substantial hourly variability during hot weather. During the June 2026 heatwave, [RTE](https://www.rte-france.com/actualites/canicule-securite-approvisionnement-electricite-appelle-aucune-vigilance-particuliere) documented output from gas-fired power plants rising from 623 MW (an ordinary day) to 4,141 MW, or 7% of the mix, in the 19:00-20:00 slot. That is when solar output declines and domestic air conditioners switch on simultaneously. The calculator above already lets you simulate the difference between average and peak mixes. It is therefore better to **pre-cool during the day** (12:00-17:00, the solar generation peak) rather than in the evening: with equal consumption, the carbon footprint can be up to 5 times lower. Detailed analysis in [Nicolas Goldberg's article on Bon Pote](https://bonpote.com/canicule-la-clim-consomme-plus-delectricite-au-gaz-que-prevu/).

## What does a carbon calculation for air conditioning miss?

This calculator already goes further than a conventional Bilan Carbone®: it separates CO₂ emissions from electricity use and refrigerant leaks, and offers a heatwave "grid peak" view. Yet 2 mechanisms remain invisible, and they matter at a collective scale:

- **The urban heat island.** An air conditioner does not eliminate heat; it expels it outside. Across a dense neighbourhood, this raises the outdoor temperature by 1 to 2 °C at night (Salamanca et al. 2014, *Journal of Geophysical Research: Atmospheres*), prompting neighbours to use more air conditioning. Cerema (the French public centre of expertise on risks, environment, mobility and planning) maps this sensitivity free of charge for 12,000 municipalities, and it is one of the measures documented in [our guide to adapting a territory](https://projetcelsius.com/en/blog/adapting-a-territory-to-climate-change/). No individual Bilan Carbone® captures this social and environmental cost.
- **The rebound effect (Jevons paradox).** Once air conditioning is installed, it is used for longer and at a lower setpoint than planned. Studies of the direct rebound effect (Greening et al. 2000 in *Energy Policy*; a review by ADEME, the French Agency for Ecological Transition) put this additional consumption at **10 to 30%** compared with the initial sizing scenarios.

## Beyond carbon, what impacts does an air conditioner have?

Climate is only one of 16 indicators in the European **Environmental Footprint (EF 3.0)** method. For each environmental dimension, a different phase of the life cycle assessment (LCA) dominates: electricity use, manufacturing, refrigerant leaks or end of life. The integrated visual, based on the reference scientific report by the **[Joint Research Centre](https://eplca.jrc.ec.europa.eu/uploads/Consumer_BoP_appliances.pdf)** (the European Commission's scientific body), shows which phase contributes most to each of the 12 main Product Environmental Footprint (PEF) indicators for a residential split air conditioner.

Of 12 indicators, **9 are dominated by the use phase** (climate, particulate matter, acidification, eutrophication, tropospheric ozone formation, fossil resources, ionising radiation, land, water), where electricity matters and, for climate, refrigerant leaks. This is what the calculator and carbon footprint capture, just as the [scope 3 of a Bilan Carbone®](https://projetcelsius.com/en/blog/scope-3-emissions-guide/) isolates an organisation's indirect emissions. Minerals and human toxicity, however, shift towards manufacturing (copper, nickel, electronic rare earths). The ozone depletion indicator mainly comes from the production chain for fluorinated refrigerants: the hydrofluorocarbon (HFC) refrigerants themselves (R32, R410A) do not deplete the ozone layer.

> **Where to act depending on the indicator.** For fine particulate matter, electricity use accounts for most of the impact: decarbonise the mix, achieve a high SEER (seasonal energy efficiency ratio), reduce cooling demand beforehand. For climate change, refrigerant also matters, contributing more than electricity in France: choose a refrigerant with a low global warming potential (GWP), such as R290, and maintain leak-tightness. For mineral and metal depletion, manufacturing matters, and the measures become extending lifespan, repairability and recycling electronic components (copper, nickel, rare earths). The ozone indicator does not depend on leaks in use: the LCA impact comes from fluorinated refrigerant production.

## Reduce demand before installing equipment: 4 measures

The first question concerns reducing demand before choosing equipment. 4 measures quantified by ADEME reduce cooling demand by 30 to 80%, allowing smaller equipment to be sized afterwards, or none at all.

- External solar protection (external venetian blinds, solar shading, shutters) cuts up to 80% of solar gains on an exposed façade, or **up to 30% lower air conditioning demand** (ADEME 2023). This is the most cost-effective measure in an existing office.
- A ceiling fan consumes 30 to 60 W, compared with 500 to 900 W for a 2.5 to 3.5 kW split at full load, or 10 to 15 times less. Combined with a thermostat set 2 to 3 °C higher, it saves around 30% of air conditioning consumption without loss of perceived comfort.
- Night-time free cooling cools the building at night with outdoor air through increased mechanical ventilation, with typical savings of 5 to 35 kWh/m²/year in commercial buildings (ADEME 2024).
- Setting the thermostat to 26 °C rather than 24 °C reduces consumption by around 14% (7% per degree), immediately and at no cost, in line with energy-saving recommendations.
- If the project allows, a reversible air-to-water or ground-source heat pump replaces a conventional air-to-air unit to good effect in new buildings or major office renovations. Their SEER (4-6 for air-to-water, 5-8+ for ground-source) is measured under different conditions from that of a split and cannot be compared like for like. Performance is also much more stable during heatwaves (ground temperature at -3 m stays around 12-14 °C). The investment is higher (€10-25k for residential ground-source versus €1-4k for a split), but the cumulative footprint over 20 years is substantially lower.

None of these measures excludes an air conditioner; they build on one another. This is the logic of an [eco-design](https://projetcelsius.com/en/blog/eco-design-process-7-steps/) process applied to thermal comfort: reduce demand first, then optimise equipment. [Alternatives to air conditioning](https://projetcelsius.com/en/blog/air-conditioning-alternatives/) (fans, ceiling fans, evaporative cooling, district cooling) are covered separately.

## Key takeaways

- In France, the electricity consumed by an air conditioner emits 5 to 10 times less CO2 than elsewhere in Europe thanks to a low-carbon electricity mix: refrigerant leaks become the leading source of use-phase emissions.
- Calculating carbon from electricity is insufficient: refrigerant leaks, the peak mix, urban heat islands and rebound effects must be included. The calculator covers part of this; multicriteria LCA complements the rest.
- Before buying, measures to reduce demand (solar protection, ceiling fans, free cooling, a 26 °C setpoint) can reduce cooling demand by 30 to 80%. Details are in our article on [alternatives to air conditioning](https://projetcelsius.com/en/blog/air-conditioning-alternatives/).
- The F-Gas timetable distinguishes between types of equipment. Regulation (EU) 2024/573 prohibits placing self-contained equipment (monobloc, plug-in) of 12 kW or less on the market with a refrigerant of GWP 150 or more from **1 January 2027**. For air-to-air split systems of the same capacity, the prohibition applies from **1 January 2029**. [The prohibition concerns placing on the market](https://projetcelsius.com/en/blog/f-gas-regulation-2027-bans/): an R32 unit bought in 2026 can still be used and maintained after that date. Since 1 January 2026, however, refrigerants with a GWP of 2,500 or more have been prohibited for maintenance without any charge threshold, making equipment still charged with R-404A impossible to recharge with virgin refrigerant.

Equipment choices made this year commit the company for 15 to 20 years. To include this line item in a formal Bilan Carbone®, see [how much a Bilan Carbone® costs](https://projetcelsius.com/en/blog/bilan-carbone-cost-france/).

## Frequently asked questions

### Should you choose a portable air conditioner or a fixed split?

A fixed split, without hesitation. Portable air conditioners have a nominal SEER of 2.5 to 3, compared with 6 to 11 for a modern wall-mounted split. For the same floor area, a portable unit consumes 2 to 4 times more electricity. Its structural weakness is sealing. The hot-air exhaust hose passes through a partly open window, creating continuous incoming outdoor (hot) air that divides the effective SEER by ~2 compared with the nominal SEER shown on the product sheet. In actual use, a portable unit therefore operates at a SEER of around 1.3-1.5. It remains a supplementary solution for an occasional room, never a long-term office strategy.

### What is the order of priorities for an office that needs cooling?

1) External solar protection (external venetian blinds, blinds) on exposed façades. 2) A ceiling fan to gain 2-3 °C of perceived comfort without air conditioning. 3) Night-time free cooling if the building allows. 4) If all this is insufficient, a modern split air conditioner, preferably R290, with a reasonable setpoint (26 °C). This sequence drastically reduces cooling demand before investing in equipment.

### How can you reduce environmental impact without giving up air conditioning?

3 measures that work together. The first is reducing cooling demand beforehand: external solar protection (external venetian blinds), a ceiling fan, night-time free cooling, a 26 °C setpoint instead of 24 °C. In a standard office, this combination divides demand by 2 to 4. The second is choosing a low-GWP refrigerant, ideally R290 (propane, GWP of 0.02 under the regulation): in France, where leaks contribute around 2 times more than electricity, it removes around 2 thirds of the use-phase footprint compared with R32. The third is maintenance: an annual leak check by a certified refrigeration engineer can divide the leak rate by 2 (from 5% to 2.5% a year) and improves actual SEER by 10 to 15%.

### How much CO₂ does air conditioning emit per year?

For a typical 30 m² office equipped with a modern split (SEER 8) in France, the calculation has 3 stages. Consumption is around 500 kWh per 4-month season. Electricity emits 500 kWh × 30 gCO2e/kWh (France mix, RTE 2024), or 15 kgCO2e/year. Leaks add more: a split this size contains around 1 kg of R32, and at 5% leakage per year, 0.05 kg × 675 gives 30 to 35 kgCO2e/year. The total is around **45 to 50 kgCO2e/year** per unit, with 2 thirds due to leaks. Multiply by 4 to 8 for an office with 25 people. The same installation in Germany (mix of around 380 gCO2e/kWh) would emit 190 kgCO2e/year from electricity alone.

### Does a fan consume less than air conditioning?

By a large margin. A fan or ceiling fan consumes 30 to 60 W, compared with 500 to 900 W for a 2.5 to 3.5 kW split at full load, or **10 to 15 times less** electricity. A fan does not cool the air, however. It speeds up sweat evaporation and gives a feeling of coolness 2 to 3 °C lower. Above 32-33 °C ambient temperature, it is no longer sufficient. It is better to switch the fan on first and use air conditioning only as a supplement, at a 26 °C setpoint. This combination divides total air conditioning consumption by 2 without loss of perceived comfort.

### Why are R32 and R410A refrigerants going to be prohibited?

European F-Gas Regulation (EU) 2024/573 sets a phase-out timetable for high-GWP refrigerants (global warming potential, meaning a refrigerant's greenhouse effect compared with CO2 over 100 years). R410A has a GWP of 2,088, R32 a GWP of 675: a 1 kg leak is equivalent to 675 or 2,088 kg of CO₂. From 1 January 2027, monobloc units of 12 kW or less can no longer be placed on the market with a refrigerant of GWP 150 or more. For air-to-air splits of 12 kW or less, the R32 prohibition (GWP 675) takes effect on **1 January 2029**, followed by a prohibition on all fluorinated gases in 2035. For these small units, the alternative is R290 (propane), with a near-zero GWP; R454B (GWP 466) is only a transitional solution, as it also exceeds the threshold of 150. R32 equipment bought today can still be used and maintained, but this technology will disappear from the small split market in 2029.

### Air conditioners, heat pumps, ground-source systems: what differs for the carbon footprint?

Technically, the thermodynamic principle is the same: a refrigerant changes state to transport heat. An air/air split, a reversible air/water heat pump and a ground-source heat pump all work this way; the difference lies in the cold or hot source (air, water, ground) and the refrigerant used. What changes the carbon footprint: equipment SEER, source stability and refrigerant GWP. Ground-source is the most efficient (SEER 5 to 8+, a stable ground temperature of 12-14 °C even during heatwaves, low leak rates in a closed circuit) and the least emissions-intensive over 20 years. However, it costs €10,000 to €25,000 (including drilling), compared with €1,000 to €4,000 for a split. It suits new buildings, major renovations or long-term commercial use; in an existing home, low-energy measures (solar protection, ceiling fans, free cooling) come first.

## Sources

**Sources**: [RTE Electricity Review 2024](https://assets.rte-france.com/prod/public/2025-03/2025-03-25-bilan-electrique-2024.pdf) (France emission factor 30 gCO₂/kWh, peak at 400-700 gCO₂/kWh); [F-Gas Regulation (EU) 2024/573](https://eur-lex.europa.eu/eli/reg/2024/573/oj) (HFC prohibition timetable 2026-2032); [IPCC AR6 WG1 Ch. 7](https://www.ipcc.ch/report/ar6/wg1/) (regulatory AR4 refrigerant GWPs); [ADEME Air Conditioning 2023](https://librairie.ademe.fr/) (office consumption, prevention measures, free cooling); [Litardo et al. 2023](https://doi.org/10.1016/j.enbuild.2023.113415) (Energy & Buildings 296:113415, systematic review of 41 air conditioner LCA studies); [Karkour 2021](https://doi.org/10.3390/en14020447) (Energies 14:447, breakdown of metals in a residential split); [Woods et al. 2022](https://doi.org/10.1016/j.joule.2022.02.007) (Joule 6:726-741, use-phase refrigerant leaks); [Riva et al. 2021](https://doi.org/10.1016/j.enbuild.2021.110894) (Energy & Buildings 240:110894, impact shifting in PV-driven systems); Greening, Greene & Difiglio 2000 (Energy Policy 28(6-7):389-401, review of direct rebound effects 10-30%); Salamanca et al. 2014 (Journal of Geophysical Research: Atmospheres 119(10):5949-5965, urban heat islands and air conditioning); [JRC Consumer Footprint Basket of Products on household appliances, EUR 29248, 2019](https://eplca.jrc.ec.europa.eu/uploads/Consumer_BoP_appliances.pdf) - Table 42, EF 3.0 PEF impact variations for a room air conditioner (RAC) between the 2010 baseline and a future low-carbon mix scenario; PEP ecopassport declarations (Product Environmental Profiles, from a French programme for electrical, electronic and HVAC equipment) available on [register.pep-ecopassport.org](https://register.pep-ecopassport.org/); [AFCE 2017 Leak Report](https://www.afce.asso.fr/wp-content/uploads/2017/03/Rapport-Final-D%C3%A9tection-Fuites-AFCE-diffusable-R-1.pdf); [Ember Climate](https://ember-energy.org/) (electricity emission factors by EU country).