# How to carry out a hospital BEGES

**Author**: Guillaume Pakula
**Published**: 2026-04-14
**Updated**: 2026-10-31
**Section**: Practical guide
**Canonical URL**: https://projetcelsius.com/en/blog/hospital-ghg-inventory-beges-guide/
**French original**: https://projetcelsius.com/blog/beges-hospitalier-mode-emploi-etablissement-sante/
**Source**: Projet Celsius (https://projetcelsius.com/en/), a climate strategy consultancy of engineers and PhDs based in Paris and Marseille.

> More than **87% of emissions** from the healthcare system fall within [scope 3](https://projetcelsius.com/en/blog/scope-3-emissions-guide/), according to The Shift Project: medical purchases, devices, food, and staff and patient travel. Since 2023, the [regulatory BEGES](https://projetcelsius.com/en/blog/beges-france-mandatory-ghg-report/) has required public establishments with more than 250 staff, general and university hospitals included, to count these indirect emissions. This guide sets out the method in 5 steps, the content of the report and how to turn it into a monitored action plan.

## Key takeaways

- **Scope 3 accounts for more than 87% of healthcare emissions**: medicines and medical devices dominate.
- **The pharmaceutical emission factors of ADEME (the French Agency for Ecological Transition) changed in March 2025**: the reference year of an earlier BEGES must be recalculated.
- **Desflurane has been banned as an anaesthetic since 1 January 2026**, except where medically necessary: for the same mass, it has 13 times the warming effect of sevoflurane.
- **A complete hospital BEGES involves 50 to 70 people** over 6 to 12 months and costs €15,000 to €30,000 excluding VAT.

In France, the healthcare sector emits around 49 MtCO2e a year, more than 8% of the country's carbon footprint, according to the [2023 report by The Shift Project](https://theshiftproject.org/app/uploads/2025/01/180423-TSP-PTEF-Rapport-final-Sante_v2.pdf) (a French climate think tank). In a hospital, the leading emission source is medicines: they account for **37%** of the [2024 Bilan Carbone®](https://www.aphp.fr/sites/default/files/2025-08/BILAN_CARBONE_2024_AP-HP.pdf) (the French carbon accounting method) of AP-HP, the Paris public hospital system, against 6.5% for energy, refrigerant leaks included. Together with laboratory consumables, medical devices, single-use products and medical gases, care accounts for 60% of its total.

This hierarchy makes a hospital BEGES (bilan d'émissions de gaz à effet de serre, France's mandatory greenhouse gas emissions report) a diagnostic for transforming procurement. Since 1 January 2023, under the decree of 1 July 2022, [Article R. 229-47](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000048878409) of the French Environmental Code has required public bodies, and therefore public hospitals, to count their significant indirect emissions: scope 3, which accounts for more than 87% of the healthcare system's emissions. Before that, the law required only direct emissions and those from purchased energy, and around a quarter of the inventories published by the sector stopped there, according to The Shift Project.

## How much does the healthcare sector emit?

### The Shift Project's figures and the sector's structure

The Shift Project has mapped [the carbon footprint of the French healthcare system (in French)](https://projetcelsius.com/blog/empreinte-carbone-systeme-de-sante/) in detail. Its 49 MtCO2e break down as follows: purchases of medicines account for 29% of the total, or 14.5 MtCO2e. Medical devices (equipment, consumables, implants) account for 21%, or 10.2 MtCO2e. Next come food (11%), travel by patients, visitors and staff (13%), durable purchases such as buildings, vehicles, machinery and IT (8%), then waste and services (5%). On-site combustion (heating, hot water, vehicles) accounts for only 9%, purchased electricity, cooling and heat for 2%, and medical gases and air conditioning for 2%. Scope 3 therefore accounts for more than 87% of the total: if you measure only the hospital's energy and vehicles, you leave out most of its emissions.

### Why medicines weigh more than energy: chemical manufacture at the core

A hospital consumes megawatts of electricity, heats thousands of square metres 24 hours a day, and sterilises continuously. Energy is visible. But a kilogram of active pharmaceutical molecule requires chemical synthesis, often in multiple stages, in a highly selective production unit. Manufacturing one gram of a molecule can require around a hundred grams of raw materials. Add the energy-intensive processes: reactors kept at controlled temperatures, distillation and chromatographic separation. Then transport from the synthesis site, often in Asia or Eastern Europe, to the French distribution centre. Finally, packaging: boxes, thermoformed blister packs and secondary packaging each have their own carbon footprint. In March 2025, [ADEME](https://www.ademe.fr/), the French Agency for Ecological Transition, updated its pharmaceutical emission factors using the FIGARO MRIO model. The pharmaceutical factor fell by about 60%, from 500 to 194 kgCO2e/k€ excl. VAT in 2023 euros (219 in 2019 euros). This figure remains a simplification, as reality varies enormously by molecule type. A generic injectable medicine does not have the same footprint as a biologically complex anticancer medicine.

## What does the law say about a hospital BEGES?

### The obligation since 2012, scope 3 since 2023

[Article L. 229-25](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000051559662) of the Environmental Code requires public bodies **with more than 250 staff** to produce and publish their greenhouse gas emissions report (BEGES), now **every 3 years**; the first report had to be drawn up by 31 December 2012. For private companies with more than 500 employees, the obligation recurs every 4 years. For healthcare establishments, this means university hospitals, general hospitals and other public establishments with more than 250 staff, private clinics with more than 500 employees and large nursing homes. Until the end of 2022, the mandatory report was limited to direct emissions and those from purchased energy: the boiler plant, electricity and vehicle fleet, nothing else. Scope 3 was optional.

The decree of 1 July 2022 widened these boundaries from 1 January 2023. Since then, significant indirect emissions, meaning the scope 3 categories that carry real weight, have been included in the mandatory boundaries for public establishments. A private clinic is required to include them only if it is subject to the sustainability statement requirement; otherwise, it may stop at direct emissions and purchased energy. Public healthcare establishments must therefore measure purchases (medicines, medical devices, services, food), travel associated with their activities (staff commuting, patient and visitor travel) and waste. A BEGES published before 2023 without scope 3 was compliant at the time; its update, 3 years later, must include it. Since the Green Industry Law (loi Industrie verte) of 23 October 2023, failure to produce or submit the report has been punishable by the administrative authority with a fine of up to €50,000, and €100,000 for a repeat offence (Article L. 229-25, III). Before that law, the ceiling was €10,000, and €20,000 for a repeat offence: these are the old figures still in circulation.

### Access to grants and public procurement criteria

The BEGES also matters for securing funding. Since 1 June 2024, the Green Industry Law has made the public grants for the ecological and energy transition awarded by the State and its operators conditional on the companies with 50 or more employees that receive them measuring their impact through a BEGES, simplified between 50 and 500 employees, according to the [Ministry of the Economy](https://www.economie.gouv.fr/actualites/que-contient-la-loi-industrie-verte). A private clinic with 50 or more employees that applies for a grant for solar panels or a heat pump is therefore affected. And since 21 August 2026, [Article L2152-7 of the Public Procurement Code](https://www.legifrance.gouv.fr/codes/article_lc/LEGIARTI000043975064) has required at least one of the award criteria for a public contract to take into account the environmental characteristics of the tender. A public hospital buying medicines, diagnostic equipment or services must therefore score environmental performance in its calls for tender. Without scope 3, it will not even know which purchases weigh the most.

The CSRD (Corporate Sustainability Reporting Directive), refocused by Directive (EU) 2026/470, known as Omnibus, applies from financial years beginning in 2027 to companies with more than 1,000 employees and more than €450 million in turnover: it adds another layer for the largest private clinic groups. But even for the smallest hospitals, the pharmaceutical and medical suppliers of these large groups will be subject to requests for carbon data. The BEGES thus becomes the foundation of supply chain transformation.

## Where do a hospital's emissions come from?

### Scopes 1 and 2: what is visible within the walls

Scope 1 groups everything the establishment produces directly. The boiler plant: natural gas, the most common fuel, heating oil in old buildings, heat pumps at modernised sites. Specialised medical gases: nitrous oxide (N₂O) in dentistry and recovery rooms, [halogenated anaesthetic gases](https://projetcelsius.com/en/blog/anaesthetic-gases-desflurane-nitrous-oxide-carbon/) in operating theatres. Desflurane has a global warming potential 2,590 times that of CO₂ over 100 years, against 195 for sevoflurane, according to Annex II of [Regulation (EU) 2024/573](https://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:32024R0573): for the same mass, 13 times more. This regulation has banned desflurane as an anaesthetic since 1 January 2026, except where it is medically necessary and the establishment keeps evidence of that need. This is a reduction opportunity that almost no hospital mentions in its initial assessment, so invisible were anaesthetic gas emissions. The internal fleet: ambulances, intra-establishment shuttles, logistics and emergencies. And fugitive emissions: refrigerants from [air conditioning](https://projetcelsius.com/en/blog/air-conditioning-environmental-impact/) (HFCs, HCFCs), nitrogen compounds from fertilisers if the establishment has farmland.

Scope 2: purchased electricity and steam. In France, electricity has a low carbon intensity thanks to the nuclear fleet: 52 to 61 gCO2e/kWh for the average mix between 2015 and 2024, according to the [Base Empreinte database of ADEME](https://base-empreinte.ademe.fr/). It therefore weighs little in a French hospital's footprint, even though consumption remains high: operating theatres, recovery rooms, heavy imaging and air conditioning run day and night. At AP-HP, energy, refrigerant leaks included, accounts for 6.5% of the 2024 assessment. This is the boundary inherited from older BEGES reports, and it is not where tonnes are saved.

### Scope 3: mapping purchases and travel

Purchases dominate. Medicines come first: 29% of the healthcare system's emissions according to The Shift Project, and 37% of AP-HP's 2024 assessment, as detailed in our article on [a hospital's Bilan Carbone®](https://projetcelsius.com/en/blog/hospital-carbon-footprint/). Here, measurement is by expenditure, not mass. A university hospital buys the full pharmacy portfolio every year: antibiotics, anticancer medicines, anticoagulants, painkillers. The second layer, medical devices, accounts for 21% of the healthcare system's emissions, or 10.2 MtCO2e according to The Shift Project: syringes, cannulas, intervention kits, scanners, monitoring equipment and ventilators. At AP-HP, they account for 7.2% of the assessment, alongside laboratory consumables (13.5%). Then services: laundry (which sterilises), cleaning (strict medical-sector protocols), maintenance (after-sales servicing of equipment) and catering for patients and healthcare staff. Then travel: a mobility survey captures staff commuting, mainly by car, because rural and suburban hospitals do not always have public transport. Patient and visitor travel to the establishment. Finally, waste: [incinerated infectious healthcare waste](https://projetcelsius.com/en/blog/infectious-healthcare-waste-carbon-footprint/), ordinary waste and laboratory chemical waste.

The technical issue in scope 3 is emission factors. Purchases are measured by budget expenditure (euros excl. VAT), using spend-based emission factors (kgCO2e/k€). ADEME maintains a table of sector factors for this purpose. Since March 2025, this table has been based on the FIGARO MRIO model, which breaks down by industrial class. For pharmaceuticals, the factor fell to around 200 kgCO2e/k€ excl. VAT (194 to 219 depending on the reference year for euros, compared with 500 previously). For medical devices, the database offers no dedicated factor: the closest sector's factor is used, for example 216 to 262 kgCO2e/k€ for computer, electronic and optical products, depending on the reference year for euros. But this average hides variation. An examination glove has nothing in common with an MRI scanner. Precision comes from a breakdown by supplier category, rather than an overall budget.

> A hospital BEGES that stops at scopes 1 and 2 misses most of the emissions, like a medical diagnosis that looked only at the patient's skin.

## How do you carry out a hospital BEGES in 5 steps?

### 1. Governance: appoint a lead and involve departments across the organisation

Hospital BEGES inventories almost always fail for the same reason: no leadership backing. The subject lands on the desk of a CSR (corporate social responsibility) intern or quality, safety and environment officer with no access to accounting data, no contacts in operational departments and no means to make things move. Our Celsius experience on the [Institut Pasteur engagement](https://projetcelsius.com/en/blog/institut-pasteur-carbon-footprint-70-contributors/) demonstrates this: 70 contributors over 3 years. Chief executive, finance director, pharmacy, procurement, technical services, operating theatres, quality, waste management and human resources for mobility. This takes time but makes the assessment possible. The committee must meet monthly, at a minimum. There must be a single lead, a CDO or CSR manager with authority to arbitrate between data requests. And this lead must have access to the executive committee, or at least a sponsor at chief executive level.

### 2. Collection: the 4 data sources and their pitfalls

The first source is energy. Supplier bills, meter readings and consumption estimated from historical records. Scopes 1 and 2 are generally easy to collect: it takes 1 to 2 weeks.

The second source is purchases, which take the longest to collect. The establishment's management accounts give an overall "pharmacy", "medical devices" or "services" budget but no internal breakdown. Information must be extracted from different systems depending on the establishment. Many university hospitals have pharmacy management software recording each purchase line, but these lines do not always have a usable category for choosing an emission factor. Medical device purchases go through procurement (supplier invoicing), but not always with the categorisation needed for emission factors. Catering sits within technical services or stores management. This is where most collection time is spent: 2 to 4 months depending on the establishment's size and IT structure. You need a breakdown of pharmaceutical spending by therapeutic category or at least by supplier, medical device spending by broad category (surgical instruments, care consumables, imaging, medical IT), and services and food budgets.

The third source is waste. Weights by waste stream from the contractor (infectious healthcare waste, waste comparable to household waste, green waste, specialised waste). Generally an Excel file with monthly tonnages. Allow 2 to 3 weeks to obtain consolidated data, unless the establishment has never weighed its waste, which happens.

The fourth source is travel. A staff commuting survey, with Google Forms sufficient for a targeted sample. An estimate for visitors, using the average number of visits per patient-day multiplied by estimated distance. This is the least precise: at AP-HP, travel accounts for 10.6% of the 2024 assessment. Allow 2 to 3 weeks with questionnaires.

### 3. Calculation and analysis: select factors and break down by category

Once the raw data have been collected, they must be converted into emissions. Scopes 1 and 2 use standard public factors. Scope 3 procurement data are the most critical. Each purchase category has a spend-based emission factor according to its NACE code or sector. ADEME maintains an up-to-date database. Since March 2025, the EMPREINTE database has used FIGARO to break down sectors. Pharmaceutical molecules have a single factor, about 200 kgCO2e/k€ excl. VAT, but in reality the footprint varies with synthesis. A generic injectable costs less than a biologically oriented anticancer medicine. The imprecision is acceptable overall but becomes visible when comparing 2 years.

What takes time is validating that the broken-down data match the factors. A BEGES still using pre-March 2025 factors overestimates the pharmaceutical category by a factor of 2.3 to 2.6, depending on the reference year for euros. A BEGES without a breakdown of purchases by category gives a flattened picture with no reduction measures.

### 4. Presentation and action plan: identify the 3 to 5 priority measures

The BEGES report must be published on the ADEME platform. But before submitting it, you must present to the executive committee: the total footprint, its breakdown by scope and category, and the 3 to 5 main categories explaining 70-80% of the inventory. For medicines, this looks like: "our pharmaceutical spending is €45 million per year, the footprint is about 9,000 tCO2e, and this is 38% of our total. The 5 most prescribed molecules, by spending volume, represent 30% of this issue." Reduction proposals follow: therapeutic alternatives (generics rather than brands), supplier negotiations on packaging, and eco-design. For medical devices, rapid decarbonisation comes from comparing single-use and reusable options (a [medical device life cycle assessment (LCA)](https://projetcelsius.com/en/blog/medical-device-carbon-footprint-lca/) quantifies this). For energy: a building thermal audit, consumption reduction and renewables where compatible. For waste: a sorting audit to reduce misclassified infectious healthcare waste and investment in pretreatment.

### 5. Publication and monitoring: create a continuous improvement process

[Publication on the ADEME website](https://projetcelsius.com/en/blog/beges-filing-ademe-platform/) is mandatory, and preparing it means ruling out [the common mistakes in a hospital BEGES (in French)](https://projetcelsius.com/blog/bilan-carbone-hopital-erreurs/). The main lever after that remains monitoring: an annual dashboard covering the 3 to 5 actions in the plan, with named people responsible, quantified indicators and quarterly milestones. "Replace 20% of pharmaceutical spending with generics by the end of 2026." "Audit infectious healthcare waste sorting and cut falsely classified infectious waste by 20% within 12 months." "Install a renewable source covering 10% of consumption by 2027." The second BEGES, 3 years later for a public establishment, starts with an improved baseline. We have seen it consistently: the first BEGES takes 6 to 12 months, the second takes 3 to 4, because the collection processes are established.

## What do completed hospital BEGES inventories show?

After several hospital engagements ([Institut Pasteur](https://projetcelsius.com/en/blog/institut-pasteur-carbon-footprint-70-contributors/), university hospitals, regional general hospitals and private clinics), 3 findings emerge without exception. Our [climate strategy guide for university hospitals](https://projetcelsius.com/en/blog/hospital-carbon-footprint/) details the specific aspects of management within a hospital establishment. The first: pharmacy is always the leading emission category, even when the director expects energy. Intuition misleads. The buildings are visible, with a gas bill and electricity bills. Medicines are invisible, just an accounting budget line. But when calculated, they always account for 29% or more. The second finding: collecting scope 3 procurement data takes 3 to 4 times longer than scopes 1 and 2 because hospital information systems are fragmented. Pharmacy has its software, procurement another, catering a third. None was designed to feed a BEGES. Data must be checked, cleaned and reconciled. The third finding is staff involvement. When a BEGES works well, it is because 50 to 70 people are involved, not only managers but department heads, operating theatre leads and pharmacists who understand the issue and propose alternatives. The return on investment lies there, in the transformation of procurement practices.

For us at Projet Celsius, a hospital BEGES is worth the 3 to 5 actions it leads the establishment to decide, owned by named people, with budgets and milestones. The establishment measures it every year, improves it and can show the regional health agency, suppliers and patients that it is making progress, which [certification by the HAS (Haute Autorité de santé, France's National Authority for Health) (in French)](https://projetcelsius.com/blog/certification-has-transition-ecologique/) will require of it from 2027 in the form of improving environmental indicators.

## Key takeaways

A hospital BEGES that stops at scopes 1 and 2 misses most of the footprint: more than 87% of the healthcare system's emissions fall within scope 3. Beyond regulatory compliance, the issue is the transformation of procurement, which accounts for more than half of a healthcare establishment's emissions. [Celsius's regulatory BEGES service](https://projetcelsius.com/en/services/beges-ghg-report/) specifies the boundaries, collection, the transition plan and the elements to prepare for publication.

- **Scope 3 accounts for more than 87% of emissions** from the healthcare system, according to The Shift Project. At AP-HP, medicines alone account for 37% of the 2024 assessment, medical devices for 7.2% and energy for 6.5%.
- **Pharmaceutical emission factors have changed** with ADEME's March 2025 update, which lowers them by about 60%. The reference year of a pre-2025 BEGES must be recalculated to remain comparable.
- Desflurane, whose **global warming potential is 13 times that of sevoflurane** for the same mass (2,590 against 195), has been **banned as an anaesthetic since 1 January 2026**, except where medically necessary.
- A successful hospital BEGES involves **50 to 70 people over 6 to 12 months**. Pharmacy, procurement, technical services, finance and operating theatres must be represented.
- Infectious healthcare waste **costs 4 to 6 times more** than ordinary waste. Optimising sorting between infectious healthcare waste and waste comparable to household waste therefore cuts both costs and the carbon footprint.

## Frequently asked questions about the hospital BEGES

### Which hospitals are required to carry out a BEGES?

Every public establishment employing more than 250 staff must publish its BEGES every 3 years (Article L. 229-25 of the Environmental Code), and every private clinic with more than 500 employees every 4 years. This means university hospitals, general hospitals, large private clinics, large nursing homes and certain specialised day hospitals if they reach the threshold. Since 1 January 2023 (decree of 1 July 2022), significant indirect emissions, the scope 3 categories that carry real weight, have been mandatory for public establishments; a private clinic is required to include them only if it is subject to the sustainability statement requirement.

### How much does a complete hospital BEGES cost, and how long does it take?

A complete scope 1-2-3 BEGES for a healthcare establishment: €15,000 to €30,000 excl. VAT depending on size and IT structure. Timeframe: 6 to 12 months, including 2 to 4 months of data collection. It costs more and takes longer than for an industrial SME (where data collection takes 4-6 weeks) because hospital information systems are fragmented. Diag Décarbon'Action, a carbon footprint programme of Bpifrance (the French public investment bank) for companies established in France, leaves €6,000 excl. VAT to pay after a 40% subsidy; it measures direct and indirect emissions and leads to an action plan. It is reserved for companies with fewer than 500 employees that have not carried out a greenhouse gas (GHG) inventory in the last 5 years. A general or university hospital, as a public establishment, therefore cannot access it, while a private clinic with fewer than 500 employees that has never produced a GHG inventory may qualify.

### How can medicine emissions be measured without detailed supplier data?

The standard method uses ADEME's spend-based factors. You have a pharmaceutical budget in euros excl. VAT and apply an emission factor (194 kgCO2e/k€ excl. VAT in 2023 euros, since March 2025). It is not perfect (a simple molecule has a lower footprint than a complex one), but it gives the correct order of magnitude. For greater precision, the Directorate-General for Enterprise (DGE) published a [public methodology](https://www.entreprises.gouv.fr/la-dge/publications/methodologie-devaluation-de-lempreinte-carbone-des-medicaments) for assessing the carbon footprint of a medicine on 5 February 2025, with a free calculation matrix: this is the "medicine carbon score", developed by the ministries responsible for industry and health with Assurance maladie (the French national health insurance scheme). The name of the start-up [Ecovamed](https://projetcelsius.com/en/blog/medicines-carbon-footprint-france-carbon-score/) appears on this guide, which is why its name is used to refer to the method. At the end of October 2025, the [Ministry of Health](https://sante.gouv.fr/sante-et-environnement/planification-ecologique-en-sante/article/medicaments-18-molecules-ciblees-pour-reduire-l-empreinte-carbone-des-hopitaux) targeted 18 priority molecules, from paracetamol to morphine, and set out in an information note how to include this score in calls for tender. Meanwhile, breaking down by therapeutic category (cardiology, respiratory medicine, oncology, antibiotics and so on) with appropriate factors gives better precision than the raw average.

### Can a healthcare establishment benefit from Diag Décarbon'Action?

Bpifrance's Diag Décarbon'Action is reserved for companies with fewer than 500 employees: a general or university hospital, as a public establishment, cannot access it. But ADEME has healthcare-specific schemes: grants for building [energy audits](https://projetcelsius.com/en/blog/energy-audit-vs-carbon-footprint/), medical device LCAs and renewable energy projects. Regions manage dedicated budgets. The best first step is to contact the regional ADEME directorate, which lists accredited BEGES providers and provides information on funding available for healthcare establishments in your region.

## Frequently asked questions

### Which scope 3 categories are critical in hospitals?

Purchases dominate: medicines account for 29% of the healthcare system's emissions according to The Shift Project and 37% of AP-HP's 2024 assessment, and medical devices for 21% and 7.2% respectively. Next come services (laundry, cleaning, maintenance, catering), then staff commuting and patient and visitor travel, which, together with business travel, account for 10.6% of AP-HP's assessment, and finally waste, including incinerated infectious healthcare waste. Purchases are measured in euros using ADEME's spend-based factors, for example 194 kgCO2e per k€ excl. VAT for pharmacy since March 2025, in 2023 euros (219 in 2019 euros), hence the value of breaking expenditure down by category.

### How are medical devices integrated into the BEGES?

Medical devices account for 21% of the healthcare system's emissions according to The Shift Project and 7.2% of AP-HP's 2024 assessment, and are included in procurement scope 3. The standard method applies ADEME's spend-based emission factors to expenditure, for example 216 to 262 kgCO2e per k€ for computer, electronic and optical products, depending on the reference year for euros. This average hides large differences, from an examination glove to an MRI scanner: you must therefore obtain from procurement a breakdown by broad category (surgical instruments, care consumables, imaging, medical IT). For the action plan, comparing single-use and reusable options, quantified through an LCA, often offers rapid decarbonisation.

### How is a hospital's BEGES published?

The BEGES and its transition plan are published on the ADEME platform (bilans-ges.ademe.fr). Before submission, present the total footprint, the breakdown by scope and the 3 to 5 categories explaining 70 to 80% of the inventory to the executive committee, with associated reduction measures. A public healthcare establishment then updates its inventory every 3 years. An annual dashboard with named people responsible, indicators and quarterly milestones enables the plan to be monitored and the next inventory prepared, often completed in 3 to 4 months compared with 6 to 12 for the first.

> In practice, start with 3 immediate actions. First: appoint a single BEGES lead and form a cross-department committee (pharmacy, procurement, technical services, finance, operating theatres). Second: check that your pharmaceutical procurement budget is broken down by supplier category, rather than just an overall total. Third: if your last BEGES predates March 2025, pharmaceutical emission factors have fallen by about 60%, so your reference year will need recalculating with the new factors. Bear in mind that more than 87% of the healthcare system's emissions are in scope 3, and medicines alone account for 37% of AP-HP's assessment. This is where the reduction measures lie, and it is why the BEGES serves as a procurement transformation tool.