UsesLevel 3 of 6 useUse, level 3 of 6Used to calculate 3 entries, levels 4 and 6Calculated with 2 entries, levels 1 and 3Database structure Read an AI-generated overview at the top of a search
The overview of a few sentences that a small model writes at the top of the results, from the excerpts of the first results. Projet Celsius estimate.
- The calculation covers reading the excerpts and writing the overview by a small model, data centre included.
- 100% of the calculation rests on database assumptions; it does not measure actual use.
- Out of scope: server manufacturing, model training, the network and the user's device.
Sentence to citeRead an AI-generated overview at the top of a search, Projet Celsius estimate: 0.061 gCO2e per search, for 0.13 Wh of electricity, servers worldwide (458 gCO2e/kWh).
- Calculated with
- Used to calculate
Breakdown of emissions by item
0.061 gCO2e in total: 0.13 Wh of electricity × 458 gCO2e/kWh (servers worldwide).
Inputs of the calculation
PUE of the data centre, Read 1,000 tokens, Write 1,000 tokens
How the calculation is built
The search itself (0.3 Wh according to Google in 2009, a figure never re-measured since) is not counted: it would take place without AI; Google does not publish the electricity use of its overviews.
Comparison with the other uses
↓ The heaviest use in the topic, "Deep research": 45 gCO2e, 750 times more
Emissions of one use, linear scale, 3 of the 5 uses in the topic, those of the same order of magnitude (at most 25 times between the smallest and the largest value). For calculated values, servers worldwide.
Characteristics
| Unit | 1 search |
|---|---|
| Default location | world, 458 gCO2e/kWh (Ember 2025, life cycle); 11 other locations to choose from |
| Counted | reading the excerpts and writing the overview by a small model, data centre included |
| Not counted | server manufacturing, model training, the network and the user's device |
| Status | estimated |
All the characteristics
| Identifier | IA-0210, projetcelsius.com/en/ai/database/IA-0210/ |
|---|---|
| Version | 0.1 of 2 November 2026 |
| Category | Uses, a request to AI |
| Choice of the selected value | database calculation from the entries this one is made of, at the quantities of the unit |
| Sources | calculation of the database |
| Licence | CC BY 4.0 |
Usage parameters
Advanced settings
Result for the chosen case
For a carbon footprint
| Item | purchases of services (GHG Protocol scope 3, category 1); regulatory BEGES, category 4 |
|---|---|
| Quantity | 1 search |
| Factor | 0.061 gCO2e per search, IA-0210 version 0.1, based on the grid at the location (location-based), servers worldwide |
| Total | 0.061 gCO2e · not counted: server manufacturing, model training, the network and the user's device |
Breakdown by item
Quantity, unit value, contribution and nature of the data for each item
| Item | Quantity | Unit value | Contribution | Share | Nature of the data |
|---|---|---|---|---|---|
| Quick question (small model, 3,000 tokens read, 150 tokens written) | × 1 | 0.13 Wh | 0.13 Wh | 100 % | assumption |
Entries that use it (3)
AI assistants worldwide, per day, Secondary school pupil, 1 year, Free personal use, 1 year
Sources of the calculation
7 publications, for this entry and those used to calculate it, with the chosen parameters.
The result is calculated by Projet Celsius. The sources below support its uses, its factors and its conversion; they do not all measure this total.
Energy and factors
The references of the selected values and of the entries used in this calculation.
Epoch AI · February 2025
Role and limits : Epoch AI
What the publication covers. the calculation from the hardware and the assumed size of the model
What it does not cover. actual measurements
Reading by the database. A public, transparent calculation
Reference of the selected value
Scope of the figure used. GPT-4o, 500 tokens written, full scope
Limit. A public calculation, from the hardware and the assumed size of the model
Role and limits : Google
What the publication covers. chips, host, standby machines, data centre, on-site water
What it does not cover. manufacturing, training
Reading by the database. The only production measurement published by a provider
Reference of the selected value
Scope of the figure used. Median of a text prompt; chips, host, standby machines, data centre
Limit. The only production measurement published by a provider, not audited by a third party
Microsoft Research · 2026
Estimation de l'énergie des requêtes en production (Joule) ↗ (new tab)
Role and limits : Microsoft Research
Author. Microsoft Research, Oviedo et al.
What the publication covers. H100 nodes, production
Reading by the database. Calibrated on production
Reference of the selected value
Scope of the figure used. Median, 500 tokens read and 300 written, H100 nodes
Limit. Not a measurement, but calibrated on production; judges public estimates to be 4 to 20 times too high
ML.ENERGY · February 2026
Role and limits : ML.ENERGY
Author. Chung et al., University of Michigan
What the publication covers. GPU energy per token, per response, per image, in steady state, according to the number of requests served at once
What it does not cover. processors, host memory, data centre cooling, manufacturing
Reading by the database. The best open benchmark: it serves to compare model sizes with each other, not as a production value
Support for the "Small model" setting
Scope of the figure used. A model of about 8 billion active parameters, like Llama 3.1 8B: about 6 times less electricity per token than the medium model, according to the ML.ENERGY benchmark.
Limit. The setting is a convention of the database supported by this publication.
Reference of the variant "Small model, about 8 billion parameters"
Scope of the figure used. Llama 3.1 8B, one H100 GPU, 64 requests at a time, GPU only, per 1,000 tokens written, reading of the question included
Limit. GPU only, on a benchmark: the database keeps only the ratio to the 70 billion model, 1 to 6.7
The measurement covers a different scope; it is not a direct measurement of this entry.
OpenAI · June 2025
Role and limits : OpenAI
Author. Sam Altman, OpenAI
What the publication covers. an average query
What it does not cover. method, scope
Reading by the database. One sentence, no method
Reference of the selected value
Scope of the figure used. "An average query", with no published method
Limit. No published scope; consistent with Google
The other publication in this section
Watershed · Aug. 2026
Estimating GHG Emissions from AI Use: Framework for Corporate-Level Measurement ↗ (new tab)
Role and limits
Author. Bistline, Ulissi, Davis, Glidden, Joyce, Li, Mohsenin and Suh (Watershed)
What the publication covers. factors per 1,000 tokens read and written at the server before PUE (host and standby machines included), PUE separate (1.10 for a large operator, 1.56 for an unknown operator)
What it does not cover. clean measurements, the model and the hardware
Reading by the database. Default factors proposed for review (public data as of June 2026); for a large operator, taken from Google's measurement published in 2025 (Elsworth et al.), which already contains the data centre overhead; constant per token, they underestimate long contexts and agents according to the authors
Reference factor: Medium model, Watershed default factor
Scope of the figure used. Default factor for 1,000 tokens read, medium model, large operator, at the server before PUE (Watershed table 2, public data as of June 2026)
Limit. This measurement concerns the reference variant, not a measurement of "Small model, about 8 billion parameters". A default value that Watershed derives from Google's measurement (0.24 Wh for the median text query of the Gemini app), with about 500 tokens per query and a written token costing 3 times a read token; Watershed does not give the split between read and written. The 0.24 Wh already include the overhead of Google's data centre (0.02 Wh, 8%): with 375 tokens read and 125 written, on the simplest reading, the factor contains it, and the PUE of 1.10 applied afterwards counts it a second time (about 9%). Values proposed for review, to be finalised in the next version of the framework
Reference factor: Medium model, Watershed default factor
Scope of the figure used. Default factor for 1,000 tokens written, medium model, large operator, at the server before PUE (Watershed table 2, public data as of June 2026)
Limit. This measurement concerns the reference variant, not a measurement of "Small model, about 8 billion parameters". 3 times the read factor, based on the write-to-read ratio adopted by Watershed (Patel et al., Splitwise, 2024). Same derivation and same caveat as for reading: Google's 0.24 Wh already include about 8% for the data centre. Values proposed for review, to be finalised in the next version of the framework
Quick question → : Data centre PUE →
The data centre, convention C3
Scope of the figure used. building cooling and losses
Limit. This figure covers part of the calculation; it does not measure the whole entry.
Reference of the selected value
Scope of the figure used. Default factor for a large operator, from the server to the data centre; 1.56 for an unknown operator
Limit. A default value, not a measurement
Conversion into carbon
The source of the electricity factor of the selected location.
Worldwide: 458 gCO2e/kWh, life cycle.
Role and limits : Ember
Author. Ember, Our World in Data
What the publication covers. electricity generation over the life cycle, by country
What it does not cover. guarantees of origin
Reading by the database. The same source for all countries
Conversion of electricity into carbon: worldwide
Scope of the figure used. the production of electricity over the life cycle, including power plant construction and fuels
Limit. An average for the chosen country, not the electricity contract or the data centre of a specific service.
Nature of the data
Published readings, conventions, assumptions
- Projet Celsius assumptions 100 %
Calculation assumptions
Quantities, nature and source of each assumption
Quick question : counted 1 times
A small model reads the excerpts of the top results, about 3,000 tokens, and writes an overview of 150 tokens
Methodology conventions
With their alternatives
| The standard query | A query counts 100 tokens read and 400 written |
|---|---|
| The data centre | Server electricity is multiplied by 1.10 for the data centre |
| The default location | Without other information, the servers are in the world, at the world average electricity |
| Electricity, location-based, on a life cycle basis | The kilowatt-hour is that of the servers' country, on a life cycle basis, from a single source for all countries |
| Two significant figures | A calculated value is rounded to two significant figures, a published value is reproduced with the precision of its source; the calculation keeps full precision |
| The formula | the sum of what makes up the entry, then CO2e: electricity (Wh) multiplied by the carbon intensity of the server location (gCO2e/kWh), divided by 1,000 |
| Calculate a case without an entry | The formula, the default values and a step-by-step example |
History
Entry in version 0.1 of 2 November 2026, in the database in version 0.4
- 2 November 2026Designation : Run a search with an AI-generated overview becomes Read an AI-generated overview at the top of a search.Independent review.
- 31 October 2026Creation of the database, in its first version (0.1).

6Territories
5Organisations
4Occupations and activities
2Machine operations
1Calculation factors















