UsesLevel 4 of 6 occupation or activityOccupation or activity, level 4 of 6Calculated with 7 entries, levels 1 and 3Database structure Automated monitoring, 1 year
A monitoring routine that runs on its own every day for a year. Projet Celsius estimate.
- "AI web search" accounts for 61% of emissions in this scenario.
- 100% of the calculation rests on database assumptions; it does not measure actual use.
- Out of scope: human reading of the monitoring output, server manufacturing and model training.
Sentence to citeAutomated monitoring, 1 year, Projet Celsius estimate: 7.6 kgCO2e per project, for 17 kWh of electricity, servers worldwide (458 gCO2e/kWh).
Breakdown of emissions by item
7.6 kgCO2e in total: 17 kWh of electricity × 458 gCO2e/kWh (servers worldwide).
Inputs of the calculation
PUE of the data centre, Read 1,000 tokens, Write, with reasoning, Re-read from cache, Web search with an AI, Web search (benchmark), Proofread a page, Deep research
How the calculation is built
50 articles sorted by a specialised model, 10 assisted searches, one summary page, one deep research run a week. The volumes are assumptions.
Comparison with other occupations and activities
Characteristics
| Unit | 1 project : 365 days |
|---|---|
| Default location | world, 458 gCO2e/kWh (Ember 2025, life cycle); 11 other locations to choose from |
| Counted | the sorting, the searches, the summaries and the cooling of the data centre |
| Not counted | human reading of the monitoring output, server manufacturing and model training |
| Status | estimated |
All the characteristics
| Identifier | IA-0334, projetcelsius.com/en/ai/database/IA-0334/ |
|---|---|
| Version | 0.1 of 2 November 2026 |
| Category | Occupations and activities, one person, one year |
| Choice of the selected value | database calculation from the entries this one is made of, at the quantities of the unit |
| Sources | calculation of the database |
| Licence | CC BY 4.0 |
Usage parameters
Advanced settings
Result for the chosen case
365 days, servers worldwide: 7.6 kgCO2e, 17 kWh.
For a carbon footprint
| Item | purchases of services (GHG Protocol scope 3, category 1); regulatory BEGES, category 4 |
|---|---|
| Quantity | 1 project |
| Factor | 7.6 kgCO2e per project, IA-0334 version 0.1, using the local grid mix (location-based), servers worldwide |
| Total | 7.6 kgCO2e · not counted: human reading of the monitoring output, server manufacturing and model training |
Breakdown by item
Quantity, unit value, contribution and nature of the data for each item
| Item | Quantity | Unit value | Contribution | Share | Nature of the data |
|---|---|---|---|---|---|
| Web search with an AI | × 3,650 | 2.7 Wh | 10 kWh | 61 % | assumption |
| Deep research | × 52 | 99 Wh | 5.1 kWh | 31 % | assumption |
| Proofread a page | × 1,830 | 0.6 Wh | 1.1 kWh | 7 % | assumption |
| Write a page | × 365 | 0.45 Wh | 170 Wh | 1 % | assumption |
| Automated workflow | × 365 | 0.24 Wh | 88 Wh | 1 % | assumption |
| Specialised task | × 18,300 | 0.002 Wh | 37 Wh | 0 % | assumption |
Entries that use it
No other entry in the database is calculated from this one.
Sources of the calculation
9 publications, for this entry and those used to calculate it, with the chosen parameters.
The result is calculated by Projet Celsius. The sources below support its uses, its factors and its conversion; they do not all measure this total.
Uses and assumptions
These publications shed light on AI tasks and uses. They do not measure the carbon footprint of the case calculated.
Anthropic · June 2025
Role and limits : Anthropic
What the publication covers. an agent uses about 4 times the tokens of a conversation, a multi-agent system about 15 times
What it does not cover. electricity
Reading by the database. Publisher orders of magnitude, with no absolute value
Deep research → : Re-read from cache →
The context re-read from cache at each of the 40 steps, 40,000 tokens on average
Scope of the figure used. server, convention C4
Limit. The quantity and the share entrusted to AI are database assumptions, not a measured footprint.
EnronSent
Role and limits : EnronSent
Author. Will Styler
What the publication covers. 96,106 messages sent by Enron employees, 13,810,266 words
What it does not cover. the messages received
Reading by the database. Professional emails from 2000 and 2001: an order of magnitude, not a norm
Automated workflow → : Read 1,000 tokens →
Length convention: an email
Scope of the figure used. A typical email: the sent messages of the Enron corpus average about 144 words; figure read in an excerpt, notice not verified
Limit. This publication supports the quantity of text or content processed, not its carbon footprint.
Google · 2026
Role and limits : Google
What the publication covers. up to hundreds of sites browsed and pages processed per search
What it does not cover. electricity
Reading by the database. A presentation page: a ceiling, not an average
Deep research → : Read 1,000 tokens →
The web pages read, about a hundred by default: Google announces up to hundreds of sites
Scope of the figure used. server, excluding the data centre
Limit. The quantity and the share entrusted to AI are database assumptions, not a measured footprint.
Projet Celsius · November 2026
Tokens per word, per line of code and per cell, measured with 7 public tokenisers
Role and limits : Projet Celsius
What the publication covers. 479,888 words from 196 blog articles and their English translation, code from the site and the Python library, a table of measurements; tokenisers of GPT-4o, GPT-4, Llama 3, Gemini (via Gemma 3), Mistral, DeepSeek and Qwen
What it does not cover. the Claude tokeniser, not public
Reading by the database. A measurement on technical texts, figures included; to be repeated if publishers change their tokeniser
Projet Celsius measurement, repeated on request with the public tokenisers
Proofread a page → : Read 1,000 tokens →
Length convention: one page
Scope of the figure used. A report page, headings and paragraphs included: between the 1,500-character sheet (250 words) and a full A4 page in single spacing (about 550 words, at 6.1 characters per word measured on our articles)
Limit. This publication supports the quantity of text or content processed, not its carbon footprint.
Proofread a page → : Write, with reasoning →
Length convention: one page
Scope of the figure used. A report page, headings and paragraphs included: between the 1,500-character sheet (250 words) and a full A4 page in single spacing (about 550 words, at 6.1 characters per word measured on our articles)
Limit. This publication supports the quantity of text or content processed, not its carbon footprint.
Write a page → : Write, with reasoning →
Length convention: one page
Scope of the figure used. A report page, headings and paragraphs included: between the 1,500-character sheet (250 words) and a full A4 page in single spacing (about 550 words, at 6.1 characters per word measured on our articles)
Limit. This publication supports the quantity of text or content processed, not its carbon footprint.
Deep research → : Write 1,000 tokens →
Length convention: one page
Scope of the figure used. A report page, headings and paragraphs included: between the 1,500-character sheet (250 words) and a full A4 page in single spacing (about 550 words, at 6.1 characters per word measured on our articles)
Limit. This publication supports the quantity of text or content processed, not its carbon footprint.
Zhang and Nam · June 2026
HANSEL: Extracting Breadcrumbs from Web Agent Trajectories for Interactive Verification ↗ (new tab)
Role and limits : Zhang and Nam
Author. Yujin Zhang and Daye Nam
What the publication covers. 45 web agent trajectories: 13.16 steps and 6.02 pages visited per task on average
What it does not cover. electricity
Reading by the database. A small sample, which gives the order of magnitude of an agent's steps
Web search with an AI → : Read 1,000 tokens →
The 5 pages found, read by the model, and the question: web agents visit 6 pages per task on average
Scope of the figure used. server, excluding the data centre
Limit. The quantity and the share entrusted to AI are database assumptions, not a measured footprint.
Energy and factors
The references of the selected values and of the entries used in this calculation.
Google · January 2009
Role and limits : Google
What the publication covers. a search, data centre
Reading by the database. Never remeasured
Reference of the selected value
Scope of the figure used. A search, data centre included
Limit. Never publicly remeasured; Google's AI answers are not published
Luccioni et al. · October 2024
Role and limits : Luccioni et al.
Author. Luccioni, Jernite and Strubell
What the publication covers. GPU, processor, memory
What it does not cover. data centre
Reading by the database. Open models only
Reference for the "Classify a text" variant
Scope of the figure used. Text classification, average of the open models tested: 0.002 kWh for 1,000 inferences
Limit. Models of 2023, measured on a node of 8 A100 GPUs
Watershed · Aug. 2026
Estimating GHG Emissions from AI Use: Framework for Corporate-Level Measurement ↗ (new tab)
Role and limits : Watershed
Author. Bistline, Ulissi, Davis, Glidden, Joyce, Li, Mohsenin and Suh (Watershed)
What the publication covers. factors per 1,000 tokens read and written at the server before PUE (host and standby machines included), PUE separate (1.10 for a large operator, 1.56 for an unknown operator)
What it does not cover. clean measurements, the model and the hardware
Reading by the database. Default factors proposed for review (public data as of June 2026); for a large operator, taken from Google's measurement published in 2025 (Elsworth et al.), which already contains the data centre overhead; constant per token, they underestimate long contexts and agents according to the authors
Reference for the variant "Medium model, Watershed default factor"
Scope of the figure used. Default factor for 1,000 tokens read, medium model, large operator, at the server before PUE (Watershed table 2, public data as of June 2026)
Limit. A default value that Watershed derives from Google's measurement (0.24 Wh for the median text query of the Gemini app), with about 500 tokens per query and a written token costing 3 times a read token; Watershed does not give the split between read and written tokens. The 0.24 Wh already include the overhead of Google's data centre (0.02 Wh, 8%): with 375 tokens read and 125 written, the simplest reading, the factor contains it, and the PUE of 1.10 applied afterwards counts it a second time (about 9%). Values proposed for review, final at the next version of the framework
Reference for the variant "Medium model, Watershed default factor"
Scope of the figure used. Default factor for 1,000 tokens written, medium model, large operator, at the server before PUE (Watershed table 2, public data as of June 2026)
Limit. 3 times the reading factor, based on the ratio between writing and reading selected by Watershed (Patel et al., Splitwise, 2024). Same derivation and same caveat as for reading: Google's 0.24 Wh already include about 8% of data centre. Values proposed for review, final at the next version of the framework
Automated workflow → : Data centre PUE →
The data centre, convention C3
Scope of the figure used. building cooling and losses
Limit. This figure covers part of the calculation; it does not measure the whole entry.
Reference of the selected value
Scope of the figure used. Default factor for a large operator, from the server to the data centre; 1.56 for an unknown operator
Limit. A default value, not a measurement
Web search with an AI → : Data centre PUE →
The data centre, convention C3
Scope of the figure used. building cooling and losses
Limit. This figure covers part of the calculation; it does not measure the whole entry.
Proofread a page → : Data centre PUE →
The data centre, convention C3
Scope of the figure used. building cooling and losses
Limit. This figure covers part of the calculation; it does not measure the whole entry.
Write a page → : Data centre PUE →
The data centre, convention C3
Scope of the figure used. building cooling and losses
Limit. This figure covers part of the calculation; it does not measure the whole entry.
Deep research → : Data centre PUE →
The data centre, convention C3
Scope of the figure used. building cooling and losses
Limit. This figure covers part of the calculation; it does not measure the whole entry.
Conversion into carbon
The source of the electricity factor of the selected location.
Worldwide: 458 gCO2e/kWh, life cycle.
Role and limits : Ember
Author. Ember, Our World in Data
What the publication covers. electricity generation over the life cycle, by country
What it does not cover. guarantees of origin
Reading by the database. The same source for all countries
Conversion of electricity into carbon: worldwide
Scope of the figure used. the production of electricity over the life cycle, including power plant construction and fuels
Limit. An average for the chosen country, not the electricity contract or the data centre of a specific service.
Nature of the data
Published readings, conventions, assumptions
- Projet Celsius assumptions 100 %
Calculation assumptions
Quantities, nature and source of each assumption
Automated workflow : × 365
One run per day
Specialised task : × 18,300
Each day, 50 articles sorted by a specialised model
Web search with an AI : × 3,650
Each day, 10 assisted searches
Proofread a page : × 1,830
Each day, 5 selected articles summarised in one page
Write a page : × 365
Each day, one summary page
Deep research : counted 52 times
One deep research per week
Methodology conventions
With their alternatives
| The standard query | A query counts 100 tokens read and 400 written |
|---|---|
| The working day and year | A working year counts 220 days and 44 weeks, a personal year 365 days; the task lists of occupations give, as a median, about 2 requests to AI per working day at low adoption, 6 at standard adoption, 21 at intensive adoption, excluding code suggestions |
| The data centre | Server electricity is multiplied by 1.10 for the data centre |
| The cache | A token re-read from the cache costs 10% of a token read |
| The default location | Without other information, the servers are in the world, at the world average electricity |
| Electricity, location-based, on a life cycle basis | The kilowatt-hour is that of the servers' country, on a life cycle basis, from a single source for all countries |
| Two significant figures | A calculated value is rounded to two significant figures, a published value is reproduced with the precision of its source; the calculation keeps full precision |
| The formula | the sum of what makes up the entry, then CO2e: electricity (Wh) multiplied by the carbon intensity of the server location (gCO2e/kWh), divided by 1,000 |
| Calculate a case without an entry | The formula, the default values and a step-by-step example |
History
Entry in version 0.1 of 2 November 2026, in the database in version 0.4
- 2 November 2026Version 0.1 of the entry, as of the date of its current value.
- 31 October 2026Creation of the database, in its first version (0.1).

6Territories
5Organisations
3Uses
2Machine operations
1Calculation factors